Technical Specifications

KANGOUROU

Kangourou Specification Modele K1 Modele K1 remorque Modele K1s
Dimensions Lenght 2991mm 4350mm 6630mm
Width 2438mm 2280mm 2280mm
Height 2591mm 2360mm 2870mm
Weight 2430kg 1740kg 1960kg
Operation storage and transportation Operation ≥5°C ≥10RH
Storage 0 to 75°C
Air filters Filtration method G4-G7
Water product and purification PH 6.8-7.2
Purification method Filters: 500 μm + activated carbon + 50μm + UV lamp
production capacity day* 1135 litres/day
Refrigerant r454c
Dispensing options ambient
Acoustic Noise level 74dba
Lifting and transportation platform Transportation Standard cargo
Lifting Forklift or crane
Electricity Nominal operation 400 3 ph 50 Hz/440 3ph 60 Hz
Allowed deviation phases not applicable
Power consumption 8.4kW 8.4kW 0
Energy efficiency* 50 Wh/litre
Circuit breaker current 40A
Main power connection 4X10mm²
Main power supply not applicable
Certifications Electrical safety CE CA CB IEC6024-41
Water safety IS-5452

TIGER

Tiger Specification Modele T3 Modele T5 Modele T10
Dimensions Lenght 6060mm 6060mm 6060mmx2
Width 2380mm 3280mm 2380mm
Height 2540mm 3540mm 3540mm
Weight 4300kg 4700kg 8800kg (4400×2)
Operation storage and transportation Operation ≥5°C ≥10RH
Storage 0 to 75°C
Air filters Filtration method G4-G7
Water product and purification PH 6.8-7.2
Purification method Filters: 500 μm + activated carbon + 50μm + UV lamp
production capacity day* 3500 litres/day 5200 litres/day 10400 litres/day
Refrigerant r454c
Dispensing options ambient
Acoustic Noise level 74dba
Lifting and transportation platform Transportation Standard cargo
Lifting Forklift or crane
Electricity Nominal operation not applicable
Allowed deviation phases not applicable
Power consumption SOLAR
Energy efficiency* 50 Wh/litre
Circuit breaker current not applicable
Main power connection not applicable
Main power supply not applicable
Certifications Electrical safety CE CA CB IEC6024-41
Water safety IS-5452

CASTOR

Castor Specification Modele C3 Modele C5 Modele C10
Dimensions Lenght 6060mm 6060mm 6060mmx2
Width 2380mm 3280mm 2380mm
Height 2540mm 3540mm 3540mm
Weight 4300kg 4700kg 8800kg (4400×2)
Operation storage and transportation Operation ≥5°C ≥10RH
Storage 0 to 75°C
Air filters Filtration method G4-G7
Water product and purification PH 6.8-7.2
Purification method Filters: 500 μm + activated carbon + 50μm + UV lamp
production capacity day* 3500 litres/day 5200 litres/day 10400 litres/day
Refrigerant r454c
Dispensing options ambient
Acoustic Noise level 78dba
Lifting and transportation platform Transportation Standard cargo
Lifting Forklift or crane
Electricity Nominal operation not applicable
Allowed deviation phases not applicable
Power consumption 0.8 litres/H00 fuel 0.8 litres/H00 fuel 2.42 litres/H00 fuel
Energy efficiency* 50 Wh/litre
Circuit breaker current not applicable
Main power connection not applicable
Main power supply not applicable
Certifications Electrical safety CE CA CB IEC6024-41
Water safety IS-5452

ELEPHANT

Elephant Specification Modele E3 Modele E5 Modele E10
Dimensions Lenght 6060mm 6060mm 6060mmx2
Width 2380mm 3280mm 2380mm
Height 2540mm 3540mm 3540mm
Weight 5300kg 5700kg 9800kg (4900×2)
Operation storage and transportation Operation ≥5°C ≥10RH
Storage 0 to 75°C
Air filters Filtration method G4-G7
Water product and purification PH 6.8-7.2
Purification method Filters: 500 μm + activated carbon + 50μm + UV lamp
production capacity day* 3500 litres/day 5200 litres/day 10400 litres/day
Refrigerant r454c
Dispensing options ambient
Acoustic Noise level 74dba
Lifting and transportation platform Transportation Standard cargo
Lifting Forklift or crane
Electricity Nominal operation 400V 50HZ 3PH or 480 60HZ 3PH
Allowed deviation phases ± 8% Voltage ± 2 Hz
Power consumption 7.3Kw 10.9kW 21.9kW
Energy efficiency* 50 Wh/litre
Circuit breaker current 25 A/32 A 63 A/68 A 120 A/135 A
Main power connection 4 Ph 4x10mm² 4 Ph 4x16mm² 4 Ph 4x35mm²
Main power supply 3 phases sockets per local regulations
Certifications Electrical safety CE CA CB IEC6024-41
Water safety IS-5452

BUFFALO

Buffalo Specification Modele C3 Modele C5 Modele C10
Dimensions Lenght 6060mm 6060mm 6060mmx2
Width 2380mm 3280mm 2380mm
Height 2540mm 3540mm 3540mm
Weight 5900kg 6300kg 9800kg (4900×2)
Operation storage and transportation Operation ≥5°C ≥10RH
Storage 0 to 75°C
Air filters Filtration method G4-G7
Water product and purification PH 6.8-7.2
Purification method Filters: 500 μm + activated carbon + 50μm + UV lamp
production capacity day* 3500 litres/day 5200 litres/day 10400 litres/day
Refrigerant r454c
Dispensing options ambient
Acoustic Noise level 74dba
Lifting and transportation platform Transportation Standard cargo
Lifting Forklift or crane
Electricity Nominal operation not applicable
Allowed deviation phases not applicable
Power consumption 0.73Nm3/H 1.2Nm3/H 2.2Nm3/H
Energy efficiency* 50 Wh/litre
Circuit breaker current not applicable
Main power connection not applicable
Main power supply not applicable
Certifications Electrical safety CE CA CB IEC6024-41
Water safety IS-5452

WALLABY

Wallaby Specification Modele WS1 Modele WS2 Modele WS3 Modele W1 Modele W2 Modele W3 Suricate S1
Dimensions Lenght 2930mm
Width 2220mm
Height 2260mm
Weight 1330kg (8 solar panels) 1410kg (16 solar panels) 1480kg (24 solar panels) 1495kg 1630kg 1790kg 1770kg (8 solar panels)
Operation storage and transportation Operation ≥5°C ≥10RH
Storage 0 to 75°C
Air filters Filtration method G4-G7
Water product and purification PH 6.8-7.2
Purification method Filters: 500 μm + activated carbon + 50μm + UV lamp
production capacity day* 150 litres/day 300 litres/day 500 litres/day 250 litres/day 500 litres/day 750 litres/day 150 litres/day
Refrigerant r454c
Dispensing options ambient
Acoustic Noise level 78dba
Lifting and transportation platform Transportation Standard cargo
Lifting Forklift or crane
Electricity Nominal operation not applicable 400V 50HZ 3PH or 480 60HZ 3PH not applicable
Allowed deviation phases not applicable ±8% Voltage ± 2 Hz not applicable
Power consumption // // // 2.8Kw 5.8Kw 8.1Kw //
Energy efficiency* 50 Wh/litre
Circuit breaker current not applicable 25 A/32 A not applicable
Main power connection not applicable 4 Ph 4 x 6mm² not applicable
Main power supply not applicable 3 Phases sockets per local regulations not applicable
Certifications Electrical safety CE CA CB IEC6024-41
Water safety IS-5452